The practical infusion pump includes weight, speed, time, sequence and drop rate modes. You will be able to set your own settings for the time and volume of the infusion, depending on each clinical case. Serious features will give you the functions of manual and automatic bolus, anti-bolus, air bubble filtering, blocking data for a certain time, as well as KVO for simultaneous infusion of several types of solution. In addition, the work is carried out using an intuitive Russian-language interface with the support of nine more foreign languages. Suitable for equipping ambulances and is actively used in treatment rooms. Lightweight and ergonomically designed, it mounts to vertical brackets with a horizontal lock option. Safety mechanisms include light and sound alarms, and you can independently adjust the volume depending on the conditions under which the infusion takes place. For autonomous work outside the hospital meets the battery, which is enough for four hours.

Advantages:

The BeneFusion VP3 volumetric pump weighs only 1.45 kilograms and has a carrying handle for easy transport. The device works from the accumulator till 4 o'clock or, optionally, up to 8 o'clock. Large monochrome LCD monitor. Intuitive controls. There is a Russian language. Visual and audible alarms - errors, deviations in operation, battery discharge, air presence and others. There is an anti-bolus function. BeneFusion VP3 meets clinical requirements. Accuracy up to + - 5 percent. Configuration according to the latest parameters. There is a display of dynamic pressure. Event log - 1500 entries, drug library - 200 drugs. Filtration of air bubbles from 50 µl, default 100 µl, can also be set to 250, 500 and 800 µl. In the “Serial” mode, there is support for secondary infusion (fractional infusion).

  • 5 intravenous infusion modes: weight, speed, time, sequence, fall rate
  • Monochrome LCD display with a diagonal of 3” and a resolution of 240 * 128 for displaying real-time information and setting system settings
  • Ergonomic housing made of impact-resistant materials with carrying handle
  • Infusion rate: 0.1-1500 ml/h in 0.1 ml/h increments
  • Volume adjustment range: 0.1-9999ml
  • Time adjustment range: 00:00:01-99:59:59
  • Total volume: 0.1-9999.99 ml in 0.1 ml increments
  • Infusion Accuracy: ≤±5%
  • KVO function: 0.1-5.0ml/h in 0.1ml/h increments with setting function, default 1.0ml/h
  • Blowing function: 800ml/h
  • Bolus function: rate in automatic and manual modes 0.2-1500 ml/h; 800ml/h default
  • 3 levels of work with blockage: low 150±113 mmHg. (20 kPa); average 525±113 mm Hg. (70 kPa); high 900±113 mm Hg (120 kPa)
  • 5 levels of air bubble filtration: 50µl, 100µl, 250µl, 500µl, 800µl; 100 µl default
  • Anti-bolus function: Prevention of over-pressurized fluid and automatic recognition of air bubbles
  • Safe infusion pause function during surgery
  • Function to change the infusion rate during operation
  • Key lock function
  • Automatic system self-diagnosis function
  • Last used settings save function
  • Medicine Library: 200 entries
  • Ability to store up to 1500 records in the system memory with subsequent transfer of information to a personal computer or laptop specialist
  • Automatic data lock function with the ability to turn on and off: the time range when turned on is 1-5 minutes. in increments of 1 min.
  • Support fixing on the dock
  • Fastening: vertical; horizontal (optional)
  • Alarms: Visual and audible warnings with 8 volume settings
  • Intuitive control without additional specialist training
  • Support 10 languages: Russian, English, Bulgarian, Chinese, Polish, Portuguese, Romanian, Turkish, French, Czech
  • Built-in lithium battery: up to 4 hours battery life when fully charged at 25ml/h; recharge time about 6 hours
  • More powerful built-in battery for 8 hours operation at 25 ml/h (optional)
  • Compatible with various IV ducts (drippers) as per GB 8368-2005 standard: diameter 3.5-4.5mm, thickness 0.8-1.2mm
  • Device class: CF, class I, protection level IP34
  • Environment when using the system: temperature 0-40ºC; humidity 15-95% (non-condensing); atmospheric pressure 57-106 kPa
  • System transport environment: -40 to 70ºC; humidity 10-95% (non-condensing); atmospheric pressure 50-106 kPa
  • Connectors: RS232; connection to the nurse's post; connection to the power supply
  • Can be installed in an ambulance according to EN-1789
  • Wi-Fi wireless module (optional)
  • Power supply: 100-240 V AC, 50/60 Hz
  • Machine dimensions: 250*90*150mm
  • Weight: up to 1.45 kg