Ultrasound machine Mindray Resona 6 Exp

Mindray Resona 6 Exp is in demand among professionals due to a large number of specialized functions. Works on the ZST platform, which allows for zone scanning, as well as channel data processing. Resona 6 Exp significantly improves image quality, which helps in diagnostics. It automatically optimizes the image when rendering complex areas. For example, the thyroid gland or small vessels. Recommended for use in public institutions.

Advantages

  • Technology:

An innovative data processing method is channel data representation based on special ZST+ technology. This is a new stage in the development of ultrasound research technologies. There is a transformation of ultrasonic parameters, which are obtained with the traditional formation of an ultrasonic beam. ZST+ technology enables innovative solutions for high quality imaging. For example, it provides enhanced acoustic imaging as well as sound velocity compensation, dynamic pixel focusing, and improved channel data representation. Based on the fully accessible sample, diagnostic imaging is performed.

  • Enhanced Acoustic Imaging

It became possible to extract more information for each frame, and the speed of imaging increased ten times than with traditional ultrasonic beam formation. This was achieved by transmitting as well as receiving signals regarding the number of large areas.

  • Sound speed compensation

The device's SI system is able to intelligently select the optimal sound speed, which provides a retrospective analysis of the received channel data. Improved image fidelity for each type of fabric. Resona 6 Exp provides adjustable tissue-specific optimization.

  • Pixel dynamic focus

The device provides unsurpassed uniformity of the image on all area of scanning at pixel level. When examining a patient, you no longer have to separately adjust the focal length in order to obtain a homogeneous image.

  • Improved processing of channel data

This significantly improved the clarity of the visualization. Multiple retrospective processing of channel data allows effective use of acoustic information for a better image. Coherent spatial synthesis: spatial combining further improves the quality of the resulting image.
HD area: Get a clearer image within the area of interest.
ZST+ technology collects and stores raw acoustic data. Therefore, the sample-based diagnostic imaging method will allow the system to perform retrospective processing of the data, as well as change the imaging parameters of the saved images. This is essential to improve clinical performance.

Additional functions:

  • RIMT

With the help of radio data, the thickness of the intima-media complex is measured. This technology is able to provide CMM thickness measurement in automatic mode. In addition, all measurements take place in real time. At the same time, they have exceptional accuracy down to 5 microns. Diagnostic accuracy also improves quantitative analysis within six cardiac cycles. In addition, there is now less dependence on image quality.

  • UWN contrast imaging

Ultra-wide non-linear imaging for contrast echography allows the system to detect and exploit non-linear primary signals as well as second harmonics. Create an image of higher quality and with a greater degree of sensitivity to secondary signals. Now lower span requirements are needed.

  • Smart Planes

Midray introduced a unique, groundbreaking technology that makes the Resona 6 Exp an innovative system in the world of ultrasound. It is able to provide fully automatic as well as accurate acquisition of important projections. It performs frequently used measurements of the fetal CNS. This results in improved performance as well as smart diagnostics and reduced user dependency. This technology is the most convenient tool for a specialist, as it can significantly increase the efficiency of scanning. This was achieved by increasing accuracy in combination with the full automation of labor-intensive work. Simply press a button to have the 3D data generated by the fetal brain scan provide information on standard CNS scanning planes: MSP, TCP, TTP and TVP. As these, measurements such as BDP, OG, LZR, Cisternae Major, Cerebellar Transverse Diameter and Lateral Ventricular Width are obtained.

  • Natural Touch elastography method

This method is able to provide excellent sensitivity and incredible reproducibility of results regardless of experience.